Automatic Transfer Switch

Automatic Transfer Switch: ZSEE KE series is suitable for AC 50Hz, with a rated current of 16~630A and a rated operating voltage of AC400V in power distribution systems. It can handle the transfer between the main power supply and backup power, making it suitable for important power systems where power outages are not permitted.

This series of switches features an integrated three-position design, classified as a CB-grade device. The motor-driven system allows for both manual and automatic power switching and supports functions such as loss of voltage, over/under voltage, and phase failure detection.

The switch is compact, easy to install, and widely used in industries like industrial, construction, petroleum, and chemical sectors.

Standards Compliance

GB14048.1 “Low-voltage switchgear and controlgear - General rules”

GB/T14048.11 “Low-voltage switchgear and controlgear - Part 6-1: Multifunctional appliances - Transfer switching equipment”

IEC60947-1 “Low-voltage switchgear and controlgear - Part 1: General rules”

IEC60947-6-1 “Low-voltage switchgear and controlgear - Multifunctional switches - Automatic transfer switching equipment”

Operating Environment

  1. Altitude does not exceed 2000 meters;

  2. Ambient temperature not higher than +40℃, not lower than -5℃;

  3. At +40℃, relative humidity does not exceed 50%;

  4. Special measures should be taken for occasional condensation caused by temperature changes;

  5. Non-explosive medium environment;

  6. No exposure to rain or snow;

  7. Enclosure protection rating: IP20;

Note: For special product requirements, please contact the company.

Model Explanation

Example of Model Selection:

ZSEEKE-160A/4 S1 160A

The ZSEEKE series automatic transfer switch, with a nominal heating current of 160A, 4 poles, CB-grade classification, controller model S1, and rated current of 160A.

Rated Operating Voltage Ue (V) Nominal Heating Current Ith (A) Poles Device Grade Controller Model Rated Operating Current Ie (A)
AC-400 63 3, 4 CB grade - 16, 20, 25, 32, 40, 50, 63
AC-400 160 3, 4 CB grade S1, S2 100, 125, 160
AC-400 250 3, 4 CB grade S1, S2 180, 200, 225, 250
AC-400 630 3, 4 CB grade S1, S2 400, 500, 630

Electrical Performance Parameters Table

Controller Function Table

ZSEEKE Terminal and Wiring Instructions

Note:

  1. Terminals 101~103 and 201~203 are active output contacts (AC230V/0.5A, no external power required);

  2. For three-pole switches, terminals 101 and 102 are neutral line terminals, and the local neutral line bus must be connected to enable the automatic transfer function.

Note:

  1. Terminals 101~104 and 201~204 are active output contacts (AC230V/0.5A, no external power required);

  2. In the mains-generator mode, terminals 301~302 input DC power (DC24V), and the startup delay function (adjustable from 0 to 180s) is initiated; if no power input, the delay is set to 0s;

  3. Terminals 501~503 are the generator startup control signal outputs;

  4. For three-pole switches, terminals 1N and 2N must be connected to the local neutral line bus to enable the automatic transfer function.

ZSEEKE Product Dimension Diagrams

Product Dimensions Table

  • As our products are continuously upgraded and optimized, all information contained in this document is subject to the actual product. Changes may occur without prior notice. Our company and employees assume no joint responsibility for any disputes arising from unconfirmed information in this document.